§ 150-15.2. AH-2 Affordable Housing 2 District.  


Latest version.
  • A. 
    Townhome area, bulk and yard requirements.
    Dimensions
    Minimum Required
    AH-2
    Lot area (acres)
    [Amended 1-25-1993 by Ord. No. 14-92]
    4
    Setback from external lot lines:
    Front yard (feet)
    50
    Side yard (feet)
    30
    Rear yard (feet)
    50
    Lot coverage:
    Minimum required open space (percent)
    35
    Accessory buildings:
    Setback from principal buildings (feet)
    40
    Setback from roadway (feet)
    30
    Unit standards:
    Distance between buildings:
    Front-to-front (feet)
    75
    Angled (feet)
    [Added 1-25-1993 by Ord. No. 14-92]
    60
    Front-to-rear (feet)
    60
    Angled (feet)
    50
    Front-to-side (feet)
    45
    Angled (feet)
    35
    Side-to-side (average distance of sidewalls) (feet)
    25
    Side-to-rear (feet)
    30
    Rear-to-rear (feet)
    75
    Building setbacks from public or private main access roads (feet)
    50
    Building setbacks from internal driveways or parking areas (feet)
    15
    Dimensions
    Maximum Permitted
    AH-2
    Gross density (units/acre)
    10
    Lot coverage:
    Building lot coverage (percent)
    20
    Total site coverage by impervious surfaces (percent)
    45
    Grades:
    Grade for improved roadways (percent)
    8
    Grade for improved driveways and parking areas (percent)
    6
    Unit Standards:
    Building or structure length (feet)
    [Amended 1-25-1993 by Ord. No. 14-92]
    180
    Number of units in single structure
    24
    Building height (feet)
    35
    Number of stories
    2
    B. 
    Multifamily dwellings, bulk and yard requirements:
    [Added 2-5-2015 by Ord. No. 1-15]
    Minimum Required
    Dimensions
    Lot area (acres)
    4
    Setback from external lot lines:
    Front yard (feet)
    40
    Side yard (feet)
    30
    Rear yard (feet)
    30
    Setback to internal roadways (feet)
    25
    Distance between buildings (feet)
    20
    Open space (percent)
    35
    Accessory building setback to:
    Principal building (feet)
    20
    Front lot line (feet)
    50
    Other lot lines (feet)
    15
    Maximum Permitted
    Dimensions
    Density (units/acre)
    10
    Building coverage (percent)
    20
    Impervious coverage (percent)
    45
    Building length (feet)
    180
    Number of units in structure (units)
    24
    Building height (stories/feet)
    3/38
Added 10-1-1992 by Ord. No. 10-92